CCT-8930 Explosion proof conductivity transmitter
The pipeline installation: conductivity data collection valve for water treatment process all the installation .
Category:
Keywords:
Product details
Applications
The pipeline installation: conductivity data collection valve for water treatment process all the installation .
Overview
CCT-8930 Explosion-proof Conductivity/Resistivity Transmitter adopts 128x64 resolution graphic dot matrix display as Human-computer interaction interface, suiting for white background backlight, can display Conductivity / Resistivity / temperature / transmission parameters at same screen. the Transmitter has advantages of simple structure, and cost-efficient.
Technical parameter
|
Description
|
CCT-8930 Explosion-proof Conductivity/Resistivity Transmitter
|
||
|
Measurement range
|
(0.05~18.25) MΩ.cm
|
(0.5~100) μs/cm
|
(1.0~1000) μs/cm
|
|
Sensor constant
|
0.01 cm-1
|
0.1 cm-1
|
1.0 cm-1
|
|
Sensor material
|
316L st.st.
|
316L st.st.
|
316L st.st.
|
|
Accuracy
|
2.0 level
|
1.5 level
|
1.5 level
|
|
Stability
|
±0.5% (FS)/24h
|
||
|
Medium temperature
|
(0 ~50)℃
|
||
|
Temperature compensation
|
25℃as standard, automatic temperature compensation
Conductivity : (0 ~100)℃ linear ;
Resistivity :(0 ~50)℃non linear;
|
||
|
Thermistor
|
pt1000
|
||
|
Transmitting
|
Output signal
|
(4~20)mA output
|
|
|
Loop resistivity
|
300Ω(Max),24VDC ;100Ω(Max),20VDC
|
||
|
Transmitting accuracy
|
±0.1mA
|
||
|
RS485 Output
|
RS485communication protocol with standard modbus
|
||
|
Power supply
|
DC 24V±4V,Non-polarity
|
||
|
Working Conditions
|
Temperature :(0~50)℃, relative humidity : ≤95%RH (non-condensing)
|
||
|
Storage
|
Temperature :(-20~60)℃,relative humidity:≤85%RH (non-condensing)
|
||
|
Pressure
|
≤0.6Mpa
|
||
|
Protection level
|
IP67(after sealed)
|
||
|
Installation
|
Pipe installation
|
||
|
Explosion-proof symbol
|
Ex ia IIC T6 Ga
|
||
|
Intrinsically safe parameter
|
Ui=28VDC Ii=95mA Pi=0.66W Ci=0.05μF Li=2mH
|
||
|
Working environmental
|
ⅡA 、 ⅡB or ⅡC;Except easy generation gas of coal mine normally used in other electrical equipments used in explosive gas environment
|
||
Workshop