POF-6900 Wall mounted FluorideV1.0
+
  • POF-6900 Wall mounted FluorideV1.0

POF-6900 Wall mounted FluorideV1.0

On-line monitoring of fluoride concentration in water and wastewater treatment in industrial processes.

Keywords:

Product details

Application fields

On-line monitoring of fluoride concentration in water and wastewater treatment in industrial processes.

Overview

The POF-6900 wall mounted Fluorine /temp transducer controller which integrates pF/F-/temperature measurement with high precision and high performance-price ratio. Measurement of Fluoride Selection Sensor with Advanced Ion Selection Technology Segmental calibration ensures the accuracy of fluoride concentration measurementit adopts a large color screen, and the scientific process design and modularized installation method can adapt to applications in various environments.
The functional channel of the instrument adopts the design of fully electrical isolation, to avoid possible conflict and interference that may occur in the composition of the various systems and applications, an excellent measurement and calculation software makes its performance synchronizing with the world famous brands.
The Control, transmission channels that can be configured freely can point to various tasks of F~ ,temperature and time, the non polarized electronic switches can work under the switching, pulse and frequency states, to meet and develop various field application.

Technical index
 

Product name POF-6900 wall mounted Fluorine /temp transducer controller
Measurcment parameter Measurement Range Resolution ratio Accuracy
Fluoride concentration ( 0.05~20.0 ) mg/L 0.01 mg/L ±10.0%%
( 20.0~200 ) mg/L 0.1 mg/L ±10.0%%
( 200~2000 ) mg/L 1 mg/L ±10.0%%
pF ( 1.00~6.00)pF 0.01pF ±0.1pF
mV ( -400.0~400.0)mV 0.01 mV ±5.0mV
Temperature ( 0.0~100.0 ) ℃ 0.1℃ ±0.5℃
temperature range of Tested solution ( 5.0-40.0 ) ℃
Temperature component Pt1000 thermal element
Control contact Channel No. 2 Channels
Technical characteristics Isolated. fully adjustable, reverse, configurable, instrument / transmitting
Loop resistance 400Ω( Max ) ,DC 24V
Transmission accuracy ±0.1mA
Channel No. 2 Channels.
Electric contact Semiconductor photoelectric switch
Programmable Each channel can be programmedand point to (temperature, pH/ORP
Technical characteristics Presetting of normally open /normally closed state / pulse /PID
Load capacity 50mA ( Max ) AC/DC 30V
Control contact2 Channel No. 1 Channel
Electric contact Relay
Programmable Each channel can be programmedand point to (temperature, pH/ORP)
Technical characteristics Presetting of normally open /normally closed state / pulse /PID
Load capacity 3AAC277V /3A DC30V
Data communication RS485,MODBUS standard protocol
Working power supply AC220V±10%
Overall power consumption <9W
Working environment Temperature: (0-50) ℃ Relative humidity: < 85% (non condensing)
Storage environment Temperature:(-20-60) ℃Relative humidity: < 85% (non condensing)
Protection level IP65
Shape size 220mmx165mmx60mm(HxWxD)
Fixed mode Wall hanging type
EMC Level 3