ROC-2015 Single Stage RO Controller
Category:
Keywords:
Product details
Application :
Small size and simple single stage integration reverse osmosis control system
Main Technical features :
|
Model |
ROC-2015 |
|
|
Single detection |
Dry Contact input |
Dry-run protection function |
|
Low-pressure protection function |
||
|
High-pressure protection function |
||
|
Water level limit |
||
|
High-pressure and low pressure flushing flushing function |
||
|
Control port |
Dry Contact output |
Water feeding solenoid valve |
|
RO flushing solenoid valve |
||
|
Booster pump |
||
|
Low-pressure water pump |
||
|
Power supply |
AC220V (±10%) 50/60Hz |
|
|
Working environment |
|
|
|
Dimension |
48×96×80mm( height ×width×depth) |
|
|
Hole size |
44×92mm(height ×width) |
|
|
Installation |
Panel mounted ,fast installtion |
|
|
Certification |
CE |
|
|
Model |
ROC-2315 |
||
|
Single detection (six channels) |
Dry Contact input |
Raw water no water protection |
|
|
Low-pressure protection |
|||
|
High-pressure protection |
|||
|
Pure water tank high level |
|||
|
External control mode signal |
|||
|
Running reset |
|||
|
Control port (five channels) |
Dry Contact output |
Raw water pump |
SPST-NO low capacity : AC220V/3A Max ;AC110V/5A Max |
|
Inlet valve |
|||
|
High pressure pump |
|||
|
Flush valve |
|||
|
Conductivity over-limit drainge valve |
|||
|
Measurement detection point |
Product water conductivity |
||
|
Measurement range |
Conductivity : 0.1~200μS/cm/1~2000μS/cm/10~999μS/cm (with different conductivity sensor ) Product water temp. : 0~50℃ |
||
|
Automatic Temperature compensation |
Temperature compensation range (0~50)℃ |
||
|
Accuracy |
1.5 level |
||
|
Power supply |
AC220V (±10%) 50/60Hz |
||
|
Working environment |
|
||
|
Dimension |
96×96×130mm( height ×width×depth) |
||
|
Hole size |
91×91mm(height ×width) |
||
|
Installation |
Panel mounted ,fast installtion |
||
|
Certification |
CE |
||
Order direction:
Basic order units:
ROC-2315 Single stage RO controller
Conductivity cell selection:
|
Conductivity cell constant |
Part No. |
|
0.1cm-1 |
CON3133-13 |
|
1.0cm-1 |
CON1134-13/CON3134-14 |
|
10.0cm-1 |
CON2136-13 |
Note : The CON1134-13 can’t be used for food,beverage ,medical or sanitary industries.
|
Model |
ROC-8221 |
||||
|
Single detection (Seven channels) |
Dry Contact input |
Raw water tank level: double channels |
Low level |
||
|
High level |
|||||
|
Pure water tank level: double channels |
Low level |
||||
|
High level |
|||||
|
Low-pressure protection |
|||||
|
High-pressure protection |
|||||
|
Pretreatment backwash signal |
|||||
|
Control port (five channels) |
Dry Contact output |
Raw water pump |
SPST-NO load capacity : AC220V/3A Max ;AC110V/5A Max;DC24V/3A Max |
||
|
Inlet valve |
|||||
|
High pressure pump |
|||||
|
Flush valve |
|||||
|
Conductivity over-limit drainge valve |
|||||
|
Measurement detection point |
Raw water conductivity ,product water conductivity ,raw water temperature , |
||||
|
Conductivity Measurement Range |
Raw Water |
10.0cm-1 |
(0-20000)μs/cm |
||
|
1.0cm-1 |
(0-2000)μS/cm |
||||
|
Product Water |
1.0cm-1 |
(0-2000)μS/cm |
|||
|
0.1cm-1 |
(0-200)μS/cm |
||||
|
Accuracy |
1.5 level |
||||
|
Working pressure of conduct cell |
(0~0.5)MPa |
||||
|
Automatic temperature compensation |
Temperature compensation range (0~50)℃ |
||||
|
Communication |
RS485 communication (Modbus protocol ) |
||||
|
Working environment |
|
||||
|
Load capability of the relay contact point |
3A/250V AC (the solenoid valve enlarges the drive capability by intermediate relay) |
||||
|
Power supply |
DC24V±4V |
||||
|
Outline dimension |
96×96×105mm ( height ×width×depth) With the back cover |
||||
|
Hole size |
91×91mm(height ×width) |
||||
|
Installation |
Panel mounted ,fast installtion |
||||
Workshop