pHORP-8930 Explosion -proof pHORP transmitter
+
  • pHORP-8930 Explosion -proof pHORP transmitter

pHORP-8930 Explosion -proof pHORP transmitter

It can be used for real-time monitoring of the pH / ORP in the flammable and explosive atmosphere (zone 0) and output the measuring the data in the types of digital (RS485) or analog (4-20mA) , connect with PLC or multi-parameter system.

Category:

Keywords:

Product details

Application
It can be used for real-time monitoring of the pH / ORP in the flammable and explosive atmosphere (zone 0) and output the measuring the data in the types of digital (RS485) or analog (4-20mA) , connect with PLC or multi-parameter system.
Overview

pH / ORP-8930 Explosion-proof pH/ORP transmitter adopts 128x64 resolution graphic dot matrix display as Human-computer interaction interface, suiting for white background backlight, can display pH / ORP / temperature / transmission parameters at same time. It uses explosion-proof cast aluminum shell,whose sealing performance is good, and it is particularly suitable for places of
thermoelectric, environmental protection, metallurgy, pharmaceutical and other industrial production area that require pH or ORP continuous monitoring.

Technical Features

Model
pH/ORP-8930
Measuring Range
pH
2~12
ORP
(-1999~+1999)mV
Temperature
(0.0 ~ 100.0) ℃ (Temperature component:Pt1000)
Resolution
pH
0.01
ORP
1mV
Temperature
0.1℃
Accuracy
pH
0.1 Level;
ORP
±5mV
Temperature
±0.5℃
Stability
pH
±0.05pH/24h
ORP
±3mV/24h
Error of output current
±0.1mA
pH Error cause by input impedance
±0.03
Equivalent input impedance
3*10 11Ω
Buffer Solution
10.00;7.00;4.00;9.18;6.86;4.01 pH buffer solution
Temperature Compensation
(0~50)℃
Power supply
DC 24V±15%
Working Environment
Temperature(0~50)℃;Relative Humidity≤85%RH (No condensation)
Storage Environment
Temperature(0~60)℃;Relative Humidity≤85%RH (No condensation)
Pressure
Normal <0.4 MPa ,Max 0.6 MPa(≤1h)
Protection Level
IP66
Installation Method
Flow device pipeline installation
External wire connection
Two-wire without polarity
Signal Output
Two-wire isolated 4-20mA analog signal RS485 communication protocol standard modbus
Explosion-proof Mark
Ex ia IIC T6 Ga
Nature safety parameters 2
Ui=28VDC Ii=95mA Pi=0.66W Ci=0.05μF Li=2mH
Using Environment
IIA、IIB and IIC;Electrical equipment for other explosive gas atmospheres other than coal mines.

 