CLA-7000 series Total chlorine (DPD) Online
+
  • CLA-7000 series Total chlorine (DPD) Online

CLA-7000 series Total chlorine (DPD) Online

Total Chlorine (DPD) Online automatic analyzer is mainly used for real-time monitoring of water plants, secondary water supply of pipe network, medical wastewater, kidney dialysis medical water, food and beverage water, swimming pools, circulating cooling water, enterprise discharge wastewater and other occasions.

Category:

Keywords:

Product details

Instrument application

Total Chlorine (DPD) Online automatic analyzer is mainly used for real-time monitoring of water plants, secondary water supply of pipe network, medical wastewater, kidney dialysis medical water, food and beverage water, swimming pools, circulating cooling water, enterprise discharge wastewater and other occasions. According to the complex and changeable working conditions on site, it is recommended that the water sample containing suspended solids be equipped with a sample supply filter system to meet the process requirements of different industries and different customers.

Overview
CLA-7000 series Total chlorine (DPD) Online automatic analyzer is a multi-index online analysis instrument that uses photoelectric colorimetry to detect Free chlorine, Total chlorine and other disinfectants, and conforms to the national standard total chlorine measurement principle. CLA-7000 series Total chlorine (DPD) Online automatic analyzer has the characteristics of simple structure, easy maintenance, long maintenance interval, accurate test data, and good stability. It can be used in medical wastewater, swimming pool water quality management, pipe network water and other occasions. At the same time, through a large number of operating practices, a water sample supply system that makes the operation of the instrument more stable has been introduced to provide you with better application solutions, so that the online analytical instrument can operate accurately and stably.
Instrument measurement principle:
Under weakly acidic conditions, free chlorine in water reacts with DPD reagent to produce red compounds. At a certain wavelength, the absorbance is measured and converted into residual chlorine based on the absorbance. In the presence of excess KI, elemental chlorine, hypochlorous acid, hypochlorite and chloramine react with the DPD reagent to form a red compound, and the absorbance is measured according to The absorbance is converted to total chlorine.
Main performance index
 
Measuring Method
N,N-Diethyl-1,4-phenylenediamine (DPD) spectrophotometry

Model

CLA-7122
CLA-7222
CLA-7123
CLA-7223
Inlet water channel
Single channel
Dual channel
Single channel
Dual channel 
Measurement range
Total Chlorine : (0.0 ~ 2.0)mg/L ,calculated as Cl2 ;
Total Chlorine : (0.5 ~10.0)mg/L ,calculated as Cl2 ;
pH:(0-14);temperature:(0-100)℃
Accuracy
Free chlorine: ±10% or 0.05mg/L (whichever is greater), calculated as Cl2; Total chlorine: ±10% or 0.05mg/L (whichever is greater), calculated as Cl2
Free chlorine: ±10% or 0.25mg/L (whichever is greater), calculated as Cl2; Total chlorine: ±10% or 0.25mg/L (whichever is greater), calculated as Cl2
pH:±0.1pH;Temp.:±0.5℃
Measurement cycle
Free Chlorine≤2.5min
Sampling interval
The interval (1~999) min can be set to any value
Maintenance cycle
Recommended once a month (see maintenance chapter)
Environmental
requirements
Ventilated and dry room without strong vibration; Suggested room temperature: (15 ~ 28)℃; relative humidity: ≤85% (no condensation).
Sample water flow
(200-400) mL/min
inlet water pressure
(0.1-0.3) bar
Inlet water temperature range
(0-40)℃
Power supply
AC (100-240)V; 50/60Hz
Consumption
120W
Power connection
3-core power cord with plug is connected to the mains socket with ground wire
Data output
RS232/RS485/(4~20)mA
Dimension size
H*W*D:(800*400*200)mm