ClO2A-7000 series Chlorine Dioxide (DPD)
Chlorine dioxide (DPD) online analyzer is mainly used for real-time monitoring of water plants, medical wastewater, wastewater discharged by enterprises, etc. According to the complex and changeable working conditions on site, it is recommended to select a sample supply filter system for water samples containing suspended solids to meet the process needs of different industries and customers.
Category:
Keywords:
Product details
Instrument application
Chlorine dioxide (DPD) online analyzer is mainly used for real-time monitoring of water plants, medical wastewater, wastewater discharged by enterprises, etc. According to the complex and changeable working conditions on site, it is recommended to select a sample supply filter system for water samples containing suspended solids to meet the process needs of different industries and customers.
Overview
ClO2A-7000 series Chlorine Dioxide (DPD) online automatic analyzer is an online analytical instrument that uses photoelectric colorimetry for the detection of Chlorine Dioxide disinfectants, which conforms to the principle of national standard Chlorine Dioxide measurement. ClO2A-7000 series Chlorine Dioxide (DPD) online automatic analyzer has the characteristics of
simple structure, easy maintenance, long maintenance intervals, accurate test data, and good stability. It can be used in tap water,sewage water plant and other occasions. At the same time, to provide you with better application solutions,, we have developed a water sample supply system that makes the operation of the instrument more stable through a large number of operating practices, so that the online analytical instrument can operate accurately and stably.
Instrument measurement principle:
Under weakly acidic conditions, Chlorine Dioxide in water reacts with DPD reagent to produce red compounds. At a certain wavelength, the absorbance is measured by spectrophotometry and converted into Chlorine Dioxide value based on the absorbance.
Technical specifications
|
Measurement range
|
N,N-Diethyl-1,4-phenylenediamine (DPD) spectrophotometry
|
|
|
Model
|
ClO2A-7101
|
ClO2A-7201
|
|
Inlet channel
|
Single channel
|
Double channel
|
|
Measurement range
|
(0.0~5.0)mg/L
|
|
|
pH:(0-14);Temperature:(0-100)℃
|
||
|
Accuracy |
ClO2:±10% or ±0.1mg/L(Accuracy take the large value )
|
|
|
pH:±0.1pH;Temperature:±0.5℃
|
||
|
Measurement Period
|
≤3.5min
|
|
|
Sampling interval
|
The interval (1~999) min can be set arbitrarily
|
|
|
Maintenance cycle
|
Recommended once a month (see maintenance chapter)
|
|
|
Environmental requirements
|
A ventilated and dry room without strong vibration;Recommended room
temperature:(15~28)℃;Relative humidity:≤85%(No condensation)
|
|
|
Water sample flow
|
(200-400) mL/min
|
|
|
Inlet pressure
|
(0.1-0.3) bar
|
|
|
Inlet water
temperature range
|
(0-40)℃
|
|
|
Power supply
|
AC (100-240)V; 50/60Hz
|
|
|
Power
|
120W
|
|
|
Power connection
|
The 3-core power cord with plug is connected to the mains socket with ground
wire
|
|
|
Data output
|
RS232/RS485/(4~20)mA
|
|
|
Size
|
H*W*D:(800*400*200)mm
|
|
Workshop