pHD/ORPD-6000
+
  • pHD/ORPD-6000

pHD/ORPD-6000

Directly used as the data acquisition terminal of the industrial field DCS and PLC system;

Category:

Keywords:

Product details

Supporting applications

• Directly used as the data acquisition terminal of the industrial field DCS and PLC system;

• Directly Access to cloud communication and big data platform through DTU of GPRS system;

• Directly use the WiFi module as a nearby wireless data collection terminal;

• The remote wireless collection terminal can be achieved through the ZigBee/Lora module;

• Optical remote data collection can be realized through optical transceiver and far infrared terminal;

• Support traditional 4-20mA industrial system (cable end RS485/4-20mA) module conversion;

• It is equipped with RS485/WiFi/USB multiple tool converters to realize APP calibration, address and baud rate search and configuration of the collection terminal;

• With the aid of the calibration PC/APP device (pHC/ORPC-6110), it can realize batch calibration in the laboratory, and replace the new humanized maintenance mode without difference on site;

• No special low-noise cable is needed for free extension in the middle, and the maximum direct distance is close to one kilometer without affecting the use.

General information

pHD/ORPD-6000 is not a traditional pH sensor, but a pHD/ORPD data acquisition terminal, which directly uses RS485 physical port to transmit data without distortion to industrial computer, PLC, touch screen and other platforms, compatible with the Internet+ and Networking with the application of traditional technology. And once wiring is used permanently.

The usual pH/ORP data acquisition mostly uses the weak electrostatic signal from the pH sensor to be connected to the meter via a cable. In the face of an electronic signal with an impedance of up to 107-12Ω, only a few hundred/ten mV, the cable and the connection medium are used in The limit is critical, the cable length is limited, and no secondary wiring is allowed in the middle.Otherwise, the impedance signal is very easy to be leaked and interfered, and the sensor must be replaced together with the cable every time the sensor is replaced.

This product has a series of patented technologies such as subversive opening split, wireless transparent transmission, no on-site APP calibration, no difference correspondence, quality improvement, product performance tracking, no secondary wiring, and cable distance of up to kilometers. The confusion of conventional industrial online pH/ORP sensors.

This pH/ORP data acquisition terminal is an IoT collection terminal, directly integrated into PLC, DCS and other systems. It can use more IoT modules to realize wired, wireless, and cloud transmission of wired, wireless, network, and optical transceivers. It is itself An IoT ecological instrument.

Main technical indicators

 

Product model

pHD/ORPD-6XXX series

Product name

pHD/ORPD data acquisition terminal

Measure item

pH

ORP

Enclosed

temperature

Measure range

2.00-12.00

(-1999-+1999)mV

(0-50)℃

Resolution

0.01

1mV

0.1℃

Accuracy

±0.1

±5mV

±0.5℃

 Working environment

 

Temperature:(-20-60)℃;  Humidity:≤90%RH(Non-condensing)

 

Withstand stress

0.4MPa

Cable length

Standard at 10m, Can support up to 200m (by appointment)

Protocol

RS485 communication (standard Modbus-RTU protocol)

Power supply

DC 9-28)V

Whole machine consumption

1.2W

Weight

0.6kg

Main material

ABS

Dimensions

φ45mm*220mm

Pipeline installation

NPT  3/4'' chemical front end   

Environmental protection bracket

 Thread:NPT3/4''

Workshop

Online inquiry


Product name:

Submit
%{tishi_zhanwei}%