LZS-Durable Plastic Tube Type Flowmeter-Thread type
Category:
Keywords:
Product details
Constaruction of LZS-15~ LZS-65
1.Joint pipe
2.Screw cap
3.O-ring
4.Upper Stop Plate
5.Scale
6.Taper Tube
7.Float
8.Lower Stop Plate

Technical Features of LZS Series Flowmeter Threaded connection
Accuracy: ±4%
Temperature: 0~60℃
Installation pressure: ≤0.6MPa
|
Model |
(DN) mm |
Range |
Size (mm) |
Suit pipe DN (mm) |
||||||||
|
Long tube |
Short tube |
Long tube type |
Short tube type |
|||||||||
|
LZS-15 |
15 |
10~100l/h 16~160l/h 25~250l/h 40~400l/h 60~600l/h
|
5~50l/h 10~100l/h 16~160l/h 25~250l/h 40~400l/h 50~500l/h 60~600l/h 100~1000l/h |
L |
D1 |
D2 |
D3 |
L |
D1 |
D2 |
D3 |
15 |
|
280 |
1/2” BSP |
26 |
45 |
202 |
1/2”BSP |
26 |
45 |
|||||
|
LZS-25 |
25 |
100~1000l/h 160~1600l/h 250~2500l/h |
100~1000l/h 160~1600l/h 250~2500l/h |
380 |
3/4” BSP |
39 |
68 |
226 |
3/4”BSP |
39 |
60 |
25 |
|
LZS-32 |
32 |
|
0.4~4m3/h 0.6~6m3/h |
|
|
|
|
288 |
1” BSP |
49.5 |
74 |
32 |
|
LZS-50 |
50 |
0.4~4m3/h 0.6~6m3/h 1~10m3/h 1.6~16m3/h (with leader) |
1~10m3/h 1.6~16m3/h |
430 |
11/2”BSP |
73 |
98 |
341 |
11/2” BSP |
73 |
98 |
50 |
|
LZS-65 |
65 |
|
2.5~16m3/h 5~25m3/h 8~40m3/h 12~60m3/h |
|
|
|
|
430 |
2” BSP |
88 |
122 |
65 |
Note:Long tube type without leader,short tube with leader.
Workshop
Online inquiry