FCT-8920 Flow Transmitter
+
  • FCT-8920 Flow Transmitter

FCT-8920 Flow Transmitter

Widely use in Water pipeline in industrial process,Single-phase fluid with low viscosity,Acid and alkali liquid with low concentration,Non-trade settlement process measurement and control.

Category:

Keywords:

Product details

Application

Widely use in Water pipeline in industrial process,Single-phase fluid with low viscosity,Acid and alkali liquid with low concentration,Non-trade settlement process measurement and control.

Performance characteristics

☆ Various setting ways of coefficient K and standard pipe diameter/non-standard pipe diameter;

☆ A variety of engineering units can be chose to meet measurement standards of different countries and areas;

☆ Internal optional (4~20)mA analog signal, instrument/transmitting dual-mode/ RS485 digital communication;

☆ Programming current transmitting between any two points in the range of whole velocity;

☆ Flow alarm, flow frequency conversion, impeller pulse frequency division, integrating volume pulse, a variety of control mode selection;

☆ DC24V centralized power supply, transmitter non-polarity connection, internal automatic identification;

☆ Good electromagnetic compatibility(EMC) design, compatible with complex electromagnetic environment of industrial field.

Technical specification 

Instrument model

FCT-8920

Measurement range

Instantaneous flow

(0~2000)m3/h

Accumulative flow

(0~99999999)m3

Flow rate

(0~5)m/s

Resolution

0.001m3/h

Refresh rate

1s

Accuracy grade

Grade 2.0

Repeatability

±0.5%

(4~20)mA output

Number of channels

Single channel

Technical features

Isolation, inversion, adjustable, instrument/transmitting dual mode

Loop resistance

300Ω(Max)、DC 24V

Transmission accuracy

±0.1mA

Control output

Number of channels

Single channel

Electrical contact

Semiconductor photoelectric relay

Load capacity

50mA(Max),AC/DC 30V

Control mode

Upper/lower limit alarm of instantaneous flow, integrating amount/pulse, instantaneous flow frequency conversion, impeller pulse frequency division

Digital output

RS485(MODBUS protocol )

Working power

source

Power supply

DC 24V±4V

Power Consumption

≤3.0W

Applicable pipe

diameter

DN25~DN350(otherwise agreed about large pipe diameter)

Working environment

Temperature:(0~50) ℃; Relative humidity: ≤85%RH(none condensation)

Storage environment

Temperature:(-20~60) ℃; Relative humidity: ≤85%RH(none condensation)

Protection grade

IP65

Installation method

Plug-in pipeline installation

Workshop

Online inquiry


Product name:

Submit
%{tishi_zhanwei}%