DCS-8600-M multi parameter controller
+
  • DCS-8600-M multi parameter controller

DCS-8600-M multi parameter controller

Widely used in water plants, distribution network line water quality analysis;

Keywords:

Product details

Applications
• Widely used in water plants, distribution network line water quality analysis;
• Cell secondary pressure tanks and other on-line analysis of multi-parameter water quality;
• Rural water supply projects, water quality change security upgrades;
• Rivers, lakes, water source protection surveillance;
• Groundwater pollution monitoring early warning system
General Description
Floor-standing DCS-8600-M Water Quality Multi-parameter online Analysis System integration platform, has a variety of online analytical parameters integrated in a single machine inside directly, centralized view and management on large touch screen panel display.
The system combines online water quality analysis, remote data transmission, database and analysis software, sensor timing of drug maintenance, systems integration timed automatic cleaning functions in one set;
It has Flexible configuration combinations. The system can integrate water turbidity, Free chlorine, CLO2, pH, ORP, temperature, Dissolved oxygen and Conductivity (TDS)
8 parameters. It can also be customized according to the actual needs of different customers, extending pressure, flow and other parameters;
Water part uses the company's application research achievement---- Self-cleaning flow analysis device, extends the maintenance cycle of the instrument, while requiring very little water sample, and has strong real-time ability. A small water sample flows through a variety of sensors being sorted by the different technology characteristics and responding order. When the water samples flow through our devices, all parameters will be measured in real time, and also can realize the expansion of external large unit;
The data transmission has multiple routes,you can use large-scale data in our server platform software for centrally view of trend analysis and remote data processing.
Customers can also build their own databases and servers for software development;
Preset internal LED lighting system. When it is necessary to maintain and look, as long as open the door the light will switch on automatically.
 
Model
DCS-8600-M
Measurement
Turbidity, Free chlorine (HCLO), Free chlorine
(CLO2),Conductivity, pH, ORP, Temperature, Dissolved
oxygen, pressure, flow
Measured range
Free chlorine
(HClO)
(0.01-2.00)mg/L;(0.01-20.00)mg/L(ppm)
Free chlorine
(ClO2)
(0.01-2.00)mg/L;(0.01-20.00)mg/L(ppm)
Turbidity
(0-100 )NTU
pH
2.00-12.00
ORP
(-2000—2000)mV
Dissolved oxygen
(0.00~20.00)mg/L(ppm)
Conductivity
(TDS)
(0-2000)μS/cm
(0-20)mS/cm
(0-2000)mS/cm
Temperature
(0.0-99.9)℃
Flow
(0-2000)m3 /h
Pressure
(0.00-1.00)MPa
Solution
Free chlorine
(HCLO)
0.01mg/L
Free chlorine
(CLO2)
0.01mg/L
Turbidity
<10NTU 0.0001NTU
>10NTU 0.001NTU
pH
0.01
ORP
1mV
Dissolved
oxygen
0.01 mg/L(ppm)
Conductivity
0.1 μS/cm
Temp.
±0.1℃
Flow
0.001 m³/h
Pressure
0.01MPa
Accuracy
Free chlorine
(HCLO)
90% confidence interval±10%FS
Free chlorine
(CLO2)
90% confidence interval±10%FS
Turbidity
<40NTU ±2.5% FS
>40NTU ±5% FS
pH
±0.1pH
ORP
±5mV
Dissolved
oxygen
±0.3mg/L(ppm)
Conductivity
±1.5%(FS)
Temp.
±0.5℃
Flow
±0.5%
Pressure
±(0.2%-0.5%)
Communication
port
RS485
MODBUS RTU
Power supply
System power supply AC 220V±10%
Working
environment
Temp.:(0-50)℃; humidity:≤85% RH(non condension)
Storage
Temp.:(0-60)℃; humidity:≤85% RH(non condension)
Cabinet size
1450mm×550mm×400mm(H×W×D)
 

Workshop


Previous:

Next:

Online inquiry


Product name:

Submit
%{tishi_zhanwei}%