MFC-8800 Internet of Things Instrument
Category:
Keywords:
Product details
Working Principle:
With the rapid development of industrial Internet of Things technology, the existence of data acquisition terminal mode of IOT instrument has become a reality, it supports RS485 output or two-wire system (4-20) mA transmission, supporting 1-4 channels of data acquisition, and internal storage of the vast majority of engineering units. It has many functions such as digital output, PID output, proportional pulse and frequency output.
Application:
For complex industrial processes, sewage treatment, water reuse, environmental monitoring, industrial field control, chemical process, thermal detection and discrete control, data transmission control and remote data transmission.
Characteristics:
• Board - card module design, easy to select onboard acquisition parameters.
• 1-4 channels of arbitrary attribute data acquisition
• 4 input parameters can be arbitrarily selected RS485/4-20mA
• Internal integrated WiFi, download the APP and view the data on the phone and set the function.
• RS485 to Lora and RS485 to ZigBee modules are used to construct wireless data transmission of the Internet of Things
• Uplink industrial RS485 interface can connect DTU to cloud data collection, view, monitoring and saving
• Internal storage of multiple units of engineering volume
• Two-way 4-20mA two-wire input
• One of the quantities can be converted to standard 4-20mA output
• The 3-way relay can be configured with any channel overrun alarm or DI associated output
• 1 channel high speed photoelectric switch port, programmable logic/pulse/frequency operation mode
Technique features:
|
Communication port |
The uplink slave channel Modbus RTU protocol RS485 port is connected with DTU and DCS Downlink master channel RS485 port of Modbus RTU protocol is connected with data acquisition terminal |
|
|
4~20mA output |
1 channel two-wire type Maximum loop resistance 400Ω |
|
|
4~20mA Input |
2 channel channel two-wire type( initiative feed) |
|
|
DI Input |
2channels Photoelectric isolation logic switch |
|
|
DO Output |
3 channels relay (only for drive signal) |
1 SPDT AC220V; 3A(MAX) |
|
2 SPST AC220V; 3A(MAX) |
||
|
1channel Photoelectric switch |
Proportional pulse/frequency Load capacity:100mA/DC30V |
|
|
Data acquisition |
Data acquisition collection,with 3 channels DC24V sensor power supply |
|
|
Display mode |
3.5”(or 4”)colorful LCD touch screen |
|
|
Power supply |
Wide power range :(12-24)V |
|
|
Consumption |
<5W |
|
|
Environment requirements |
Environment temp:(5~45)℃; relative humidity:≤90%。 |
|
|
Hole dimension |
(91×91)mm hole dimension;panel dimension(100*100)mm |
|
Main technical features:
|
Communication Port |
Uplink slave channel: Modbus RTU protocol RS485 port is connected with DTU and DCS Downlink master channel:RS485 port of Modbus RTU protocol is connected with data acquisition terminal |
|
|
4~20mA output |
1 channel two-wire type Maximum loop resistance 400Ω |
|
|
4~20mA input |
2 channel channel two-wire type( initiative feed) |
|
|
DI input |
2channels Photoelectric isolation logic switch |
|
|
DO ouput |
3 channels relay (only for drive signal) |
1 SPDT AC220V; 3A(MAX) |
|
2 SPST AC220V; 3A(MAX) |
||
|
1channel Photoelectric switch |
Proportional pulse/frequency Load capacity:100mA/DC30V |
|
|
Data acquisition |
Data acquisition collection,with 3 channels DC24V sensor power supply |
|
|
Display mode |
3.5”(or 4”)colorful LCD touch screen |
|
|
Power supply |
Wide power range:(12-24)V |
|
|
Consumption |
<5W |
|
|
Environment requirement |
Environment temp:(5~45)℃; relative humidity:≤90%RH。 |
|
|
Hole size |
(91×91)mm hole dimension;panel dimension(100*100)mm |
|
Workshop
Online inquiry